Union HP850-K Alternative Solvent
Union HP850-K Alternative Solvent
Product Description
| WORKING MACHINE WITH SOLVENT: | HYDROCARBON / GREEN EARTH / SOLVON K4 | ||||
| MACHINE CAPACITY (RATIO 1:20) | Lbs | 45 ÷ 50 | |||
| BASKET | |||||
| Diameter | inches | 39.4 | |||
| Depth | inches | 20 | |||
| Volume | cu-ft | 14.1 | |||
| Wash speed | rpm | 12 ÷ 50 | |||
| Extract speed | rpm | 300 ÷ 540 | |||
| Door opening | inches | 20 | |||
| SOLVENT TANKS | |||||
| Useful volume tank 1 | gal | 32 | |||
| Useful volume tank 2 | gal | 48 | |||
| FLOOR SAFETY TANK CAPACITY | gal | 89 | |||
| DESTILLATOR | |||||
| Useful volume at half inspection | gal | 50 | |||
| Total volume | gal | 60 | |||
| Boiler water capacity | gal | 4 | |||
| ELECTRIC POWER | (220V – 60Hz) | ||||
| Wash motor – Extract motor | Hp | 7.5 | Kw | 5.6 | |
| Solvent pump motor | Hp | 1 | Kw | 0.75 | |
| Fan motor | Hp | 3 | Kw | 2.25 | |
| Refrigerator compressor | Hp | 7 | Kw | 5.25 | |
| Nylon filter motor | Hp | 0.75 | Kw | 0.56 | |
| Vacuum pump motor | Hp | 0.5 | Kw | 0.38 | |
| Still electric elements | Hp | Kw | 13.5 | ||
| Heater electric elements | Hp | Kw | 12 | ||
| Air motor compressor | Hp | 0.5 | Kw | 0.37 | |
| Button trap drying blower | Hp | 0.75 | Kw | 0.55 | |
| NOTE: Acoustic emission level of the machine is lower than 70 dB (A) | |||||
| Version – 03 | ONE NYLON FILTER | ||||
| Volume nylon filter housing | gal | 14.5 | |||
| Nylon filter area | ft² | 42 | |||
| Filter disks | nr | 26 | |||
| Version – 08 | ONE NYLON FILTER AND ONE DECOLORATING FILTER | ||||
| Volume nylon filter housing | gal | 14.5 | |||
| Nylon filter area | ft² | 42 | |||
| Filter disks | nr | 26 | |||
| Decolorating housing volume | gal | 3.4 | |||
| Decolorating cartridges | nr | 1 | |||
| Decolorating cabon quantity | Lbs | 4.4 |